Even when the load is a constant current, the output fluctuates at the beginning of the flow of the load current and at other times, and so it is probably necessary to check the degree of stability through waveforms. Moreover, if the crossover frequency is low (that is, response characteristics are poor), overshoot of the output voltage on startup may be large, and so once again, waveforms should be checked.