For the BAxxCC0 series of LDOs, the error of the output voltage is listed as ±2% at VCC=10V, but what is the output voltage error in the range of VCC=6V to 12V?
In the range from VCC=6V to 12V input voltage variation is added and the error is ±3% (reference). When increased accuracy is required, consider the BDxxFC0FP series with an output voltage accuracy of ±1%. And even when input voltage variation is taken into account the accuracy is still just ±2%.