ROHM FAQ

FAQ's
  • Is it possible to restore from the STOP mode using UART, A/D converter, and timer?
    • Because all clocks stop in the STOP mode, restoration cannot be done with UART, A/D converter, and timer. Restoration is possible from the Deep-HALT, HALT-H, and HALT mode with LTBC, timer, and multi-purpose function timer.
      It is possible to restore from the HALT-H and HALT mode with the A/D converter.

      Related Products: ML610(Q)40x, ML610(Q)42x, ML610(Q)47x, ML610(Q)48x, ML610Q10x, ML610Q11x, ML610Q17x, ML610Q30x, ML610Q35x, ML610Q36x, ML610Q38x, ML610Q41x, ML610Q43x, ML610Q46x, ML620Q13x, ML620Q15x, ML620Q416/ML620Q418, ML620Q503H/ML620Q504H/ML620Q506H, ML62Q12xx, ML62Q13xx, ML62Q14xx, ML62Q15xx/ML62Q18xx, ML62Q16xx, ML62Q17xx

    • Produkte: General-purpose MCUs (16bit) , Speech Playback MCUs (8bit)